Status of the CEBAF (Continuous Electron Beam Accelerator Facility) injector
The injector for the CEBAF cw superconducting linac consists of a 100 keV electron gun, two choppers and a buncher. A short, room temperature, graded-{beta}, sidecoupled accelerator is used to increase the electron beam energy to about 500 keV to produce a good match into the first superconducting accelerator cavity. Eighteen five-cell superconducting cavities are used to produce an energy of 45 MeV before injection into the first linac. All of the room temperature centerline hardware has been installed on a strongback. Testing of the 100 keV electron gun and transport system is in progress. The rf system for the choppers and buncher is nearly complete and the first rf tests are in progress. 5 refs., 7 figs., 1 tab.
- Research Organization:
- Southeastern Universities Research Association, Newport News, VA (USA). Continuous Electron Beam Accelerator Facility
- Sponsoring Organization:
- DOE/ER
- DOE Contract Number:
- AC05-84ER40150
- OSTI ID:
- 5481213
- Report Number(s):
- DOE/ER/40150-102; CEBAF-PR--89-027; CONF-881049--77; ON: DE90000757
- Country of Publication:
- United States
- Language:
- English
Similar Records
Operation of the RF Controls in the CEBAF Injector
Operation of the rf controls in the CEBAF injector
Related Subjects
430302* -- Particle Accelerators-- Injection & Extraction Systems
ACCELERATORS
BEAM BUNCHERS
BEAM INJECTION
BEAM PULSERS
BEAM TRANSPORT
CAVITY RESONATORS
CEBAF ACCELERATOR
DESIGN
ELECTRONIC EQUIPMENT
EQUIPMENT
LINEAR ACCELERATORS
RESONATORS
SUPERCONDUCTING CAVITY RESONATORS