The SO/sub 2/ removal efficiency with the adipic acid averaged 94.3% over a 30-day period, representing a significant improvement in the performance of the system using only limestone. Economic calculations for an industrial boiler adipic-acid-enhanced limestone FGD system indicate a slight reduction in both capital and operating expenses relative to a limestone-only system designed for 90% SO/sub 2/ control of 3.5% sulfur coal. The costs are competitive with the dual alkali system. The successful demonstration of the adipic-acid-enhanced limestone system increases the number of demonstrated technologies available to a potential user.