Adipic acid enhanced flue gas desulfurization process for industrial boilers: Volume 1. Field test results. Project summary

Technical Report ·
OSTI ID:5474222
Test results show that adding adipic acid to the limestone slurry significantly improved the SO/sub 2/ removal efficiency of the FGD system. Limited baseline data on operations with limestone only indicated a performance level of 55% SO/sub 2/ removal. Adding about 2200 ppM of adipic acid to the limestone scrubbing systems, the unit's level of performance increased to an average of 94.3% SO/sub 2/ removal which was maintained within a standard deviation of 2.2% over a 30-day test period during which boiler load was 70 to 130 million Btu/hr and gas throughput varied 300%.
Research Organization:
Environmental Protection Agency, Research Triangle Park, NC (USA). Industrial Environmental Research Lab.
DOE Contract Number:
AI01-80EV10473
OSTI ID:
5474222
Report Number(s):
EPA-600/S7-82-065a-Vol.1; ON: DE85016812
Country of Publication:
United States
Language:
English