The portable High-Level Neutron Coincidence Counter is used to assay the /sup 240/Pu-effective loading of a reference mixed-oxide fuel assembly by neutron coincidence counting. We have investigated the effects on the coincidence count rate of the total fuel loading (UO/sub 2/ + PuO/sub 2/), the fissile loading, the fuel rod diameter, and the fuel rod pattern. The coincidence count rate per gram of /sup 240/Pu-effective per centimeter is primarily dependent on the total fuel loading of the assembly; the higher the loading, the higher the coincidence count rate. Detailed procedures for the assay of mixed-oxide fuel assemblies are developed.
Research Organization:
Los Alamos National Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
5262977
Report Number(s):
LA-9318-MS; ON: DE82015083
Country of Publication:
United States
Language:
English