This paper describes the principal characteristics of a system of scintillation hodoscopes based on GFEU-30 photomultipliers that is used as a track detector in beams of relativistic particles with an intensity of less than or equal to 5.6 X 10/sup 6/ sec /sup -1/. Particle coordinates are determined by six double scintillation hodoscopes based on hodoscopic photomultipliers. A block diagram of the recording channel of one hodoscope is shown. Experimental and calculated space resolutions for FSP and BUD-17 circuits as functions of the time shift are shown.
Research Organization:
Institute of High-Energy Physics, Serpukhov
OSTI ID:
5258519
Journal Information:
Instrum. Exp. Tech. (Engl. Transl.); (United States), Journal Name: Instrum. Exp. Tech. (Engl. Transl.); (United States) Vol. 29:1, PT. 1; ISSN INETA