Problems plague startup of Palo Verde nukes: NRC proposes fines for QA deficiencies, records falsification

Journal Article · · Electr. Light Power; (United States)
OSTI ID:5227862

Defective coolant pump design in unit one and a failure to get adequate rate relief from the Arizona Corporation Commission to cover the 16% cost overruns are delaying commercial operation at Phoenix's Palo Verde nuclear plant. Arizona Public Service (APS) Company's deteriorating financial situation caused the utility to scrap a program to credit customers who purchase energy-saving devices and threatens more extreme action. The Nuclear Regulatory Commission fined APS for alleged quality assurance (QA) violations following a construction appraisal inspection at unit one and reports of falsified installation records. APS argues that its own inspectors would have found the missing bolts and the caps installed on pressure-sensing lines, but concedes the QA lapses. The company challenges NRC's report of a possible 150 falsifications, and concedes only one. The NRC imposes a $40,000 fine on each violation. (DCK)