Reconstruction of truncated TCT and SPECT data from a right-angle dual-camera system for myocardial SPECT

Conference ·
OSTI ID:513268
; ;  [1]
  1. Univ. of North Carolina, Chapel Hill, NC (United States); and others

We investigated methods to accurately reconstruct 180{degrees} truncated TCT and SPECT projection data obtained from a right-angle dual-camera SPECT system for myocardial SPECT with attenuation compensation. The 180{degrees} data reconstruction methods would permit substantial savings in transmission data acquisition time. Simulation data from the 3D MCAT phantom and clinical data from large patients were used in the evaluation study. Different transmission reconstruction methods including the FBP, transmission ML-EM, transmission ML-SA, and BIT algorithms with and without using the body contour as support, were used in the TCT image reconstructions. The accuracy of both the TCT and attenuation compensated SPECT images were evaluated for different degrees of truncation and noise levels. We found that using the FBP reconstructed TCT images resulted in higher count density in the left ventricular (LV) wall of the attenuation compensated SPECT images. The LV wall count density obtained using the iteratively reconstructed TCT images with and without support were similar to each other and were more accurate than that using the FBP. However, the TCT images obtained with support show fewer image artifacts than without support. Among the iterative reconstruction algorithms, the ML-SA algorithm provides the most accurate reconstruction but is the slowest. The BIT algorithm is the fastest but shows the most image artifacts. We conclude that accurate attenuation compensated images can be obtained with truncated 180{degrees} data from large patients using a right-angle dual-camera SPECT system.

OSTI ID:
513268
Report Number(s):
CONF-961123--; CNN: Grant CA39463
Country of Publication:
United States
Language:
English

Similar Records

Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Conference · Wed Nov 30 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6705193

Comparison of 180{degree} and 360{degree} iterative reconstruction with non-uniform attenuation compensation for Tl-201 SPECT
Journal Article · Tue Aug 01 00:00:00 EDT 1995 · IEEE Transactions on Nuclear Science · OSTI ID:148079

Quantitative SPECT reconstruction of iodine-123 data
Journal Article · Thu Feb 28 23:00:00 EST 1991 · Journal of Nuclear Medicine; (USA) · OSTI ID:6042239