Magnetic measurements on an in-vacuum undulator for the NSLS x-ray ring

Conference ·
OSTI ID:493387
Magnetic measurements have been performed on the In-Vacuum Undulator (IVUN), built jointly by BNL and SPring-8 for the NSLS X-ray Ring. The IVUN magnet has a Halback-type, pure-permanent magnet structure with a period of 11 mm and a minimum gap of 2 mm. Results of magnetic measurements utilizing Hall probe, moving wire and pulsed wire techniques will be presented and compared.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
493387
Report Number(s):
BNL--63974; CONF-970503--70; ON: DE97006725
Country of Publication:
United States
Language:
English

Similar Records

Initial Results from an In-Vacuum Undulator in the NSLS X-ray Ring
Conference · Fri Oct 31 23:00:00 EST 1997 · OSTI ID:629298

NSLS IN-VACUUM UNDULATORS AND MINI-BETA STRAIGHTS.
Conference · Mon Jun 18 00:00:00 EDT 2001 · OSTI ID:914484

Impedance of the NSLS prototype small-gap undulator vacuum chamber