NSLS IN-VACUUM UNDULATORS AND MINI-BETA STRAIGHTS.
Conference
·
OSTI ID:914484
We review the work carried out in the X13 R&D Straight Section of the NSLS X-Ray Ring on small gap in-vacuum undulators (IVUNs). Then we discuss: (1) plans to replace the pure permanent magnet undulator in X13 by a hybrid design providing stronger magnetic fields, enhancing the tunability of the device; (2) plans to install hybrid IVUNs in the two RF straights of the X-Ray Ring, increasing the number of insertion devices in the XRay Ring to eight; (3) the possibility of reducing the vertical beta function in the X13 straight from 0.33 m down to 0.16 m. This reduction in beta function would allow us to decrease the usable undulator gap from 3mm down to 2mm, further increasing the tuning range.
- Research Organization:
- BROOKHAVEN NATIONAL LABORATORY
- Sponsoring Organization:
- Doe - Office Of Energy Research
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 914484
- Report Number(s):
- BNL--68403; KC0204011
- Country of Publication:
- United States
- Language:
- English
Similar Records
The NSLS X13 Mini-Gap Undulator: Design and Performance
Insertion device development in the X13 straight of the NSLS X-Ray Ring
Initial Results from an In-Vacuum Undulator in the NSLS X-ray Ring
Journal Article
·
Wed May 12 00:00:00 EDT 2004
· AIP Conference Proceedings
·
OSTI ID:20652930
Insertion device development in the X13 straight of the NSLS X-Ray Ring
Conference
·
Tue Jul 01 00:00:00 EDT 1997
·
OSTI ID:495808
Initial Results from an In-Vacuum Undulator in the NSLS X-ray Ring
Conference
·
Fri Oct 31 23:00:00 EST 1997
·
OSTI ID:629298