Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Insertion device development in the X13 straight of the NSLS X-Ray Ring

Conference ·
OSTI ID:495808
On the NSLS X-Ray Storage Ring, the X13 straight section and beamline have been used for insertion-device-related R and D since 1990. The authors will describe three important projects: The Prototype Small-Gap Undulator (PSGU), the In-Vacuum Undulator (IVUN), and the Time Varying Elliptically Polarized Wiggler (EPW). The PSGU has successfully operated with a vertical aperture of only 3 mm, with minimal reduction in electron beam lifetime. The EPW has successfully run during regular user operations while switching at either 2 Hz or 100 Hz, with no adverse effects on other experiments. The IVUN project is a collaboration between NSLS and Spring-8, and installation is scheduled for May 1997.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Energy Research, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
495808
Report Number(s):
BNL--64470; CONF-970503--72; ON: DE97006722
Country of Publication:
United States
Language:
English

Similar Records

NSLS IN-VACUUM UNDULATORS AND MINI-BETA STRAIGHTS.
Conference · Mon Jun 18 00:00:00 EDT 2001 · OSTI ID:914484

Operation of a small-gap undulator on the NSLS X-ray Ring
Conference · Sat Dec 31 23:00:00 EST 1994 · OSTI ID:10108324

Initial Results from an In-Vacuum Undulator in the NSLS X-ray Ring
Conference · Fri Oct 31 23:00:00 EST 1997 · OSTI ID:629298