Impedance of the NSLS prototype small-gap undulator vacuum chamber
- Stanford Linear Accelerator Center, Menlo Park, CA (United States)
- Brookhaven National Lab., Upton, NY (United States)
Insertion device performance is limited by the minimum magnet gap allowed by storage ring beam dynamics. In this note, we analyze the impedance of the vacuum chamber for the prototype small-gap undulator being built for the NSLS X-Ray ring, and discuss the consequent beam instability thresholds.