Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Leak detection capability in CANDU reactors

Conference ·
OSTI ID:489338
This paper addresses the moisture leak detection capability of Ontario Hydro CANDU reactors which has been demonstrated by performing tests on the reactor. The tests confirmed the response of the annulus gas system (AGS) to the presence of moisture injected to simulate a pressure tube leak and also confirmed the dew point response assumed in leak before break assessments. The tests were performed on Bruce A Unit 4 by injecting known and controlled rates of heavy water vapor. To avoid condensation during test conditions, the amount of moisture which could be injected was small (2-3.5 g/hr). The test response demonstrated that the AGS is capable of detecting and annunciating small leaks. Thus confidence is provided that it would alarm for a growing pressure tube leak where the leak rate is expected to increase to kg/hr rapidly. The measured dew point response was close to that predicted by analysis.
Research Organization:
Nuclear Regulatory Commission, Washington, DC (United States). Div. of Engineering Technology; Electricite de France (EDF), 69 - Villeurbanne (France); Battelle, Columbus, OH (United States)
OSTI ID:
489338
Report Number(s):
NUREG/CP--0155; CONF-9510432--; ON: TI97004806
Country of Publication:
United States
Language:
English

Similar Records

Leak-before-break experience in CANDU reactors
Conference · Thu Dec 31 23:00:00 EST 1987 · Trans. Am. Nucl. Soc.; (United States) · OSTI ID:6947642

CANDU can and does
Journal Article · Wed Feb 28 23:00:00 EST 1973 · Des. Eng. (Toronto), v. 19, no. 3, pp. 42-44 · OSTI ID:4383142

CANDU nuclear reactor and process heat: Canadian experience and recent new developments
Journal Article · Wed Dec 31 23:00:00 EST 1980 · Am. Soc. Mech. Eng., (Pap.); (United States) · OSTI ID:5341265