A FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER WITH APPLICATIONS. Technical Paper No. 176
Technical Report
·
OSTI ID:4842753
A versatile neutron time-of-flight spectrometer suitable for use in the millimicrosecond region is described. Either the r-f beam deflection method or the gamma coincidence method is used to provide the zero-time indication. Details of the methods, along with spectra obtained for some (d,n) reactions, are given. The two systems are compatible and make use of the same simple time- topulse-height converter. The dependence of the decay time of a liquid scintillator on the specific ionization of the detected particle was used to make the neutron detector insensitive to gamma-rays. (auth)
- Research Organization:
- Canada. Suffield Experimental Station, Ralston, Alberta
- NSA Number:
- NSA-15-029397
- OSTI ID:
- 4842753
- Report Number(s):
- NP-9575
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
A fast neutron time-of-flight spectrometer
Journal Article
·
Sat Oct 31 23:00:00 EST 1959
· Rev. Sci. Instr.
·
OSTI ID:4196632
FAST NEUTRON TIME-OF-FLIGHT SPECTROMETER
Technical Report
·
Tue May 01 00:00:00 EDT 1962
·
OSTI ID:4776791
A fast neutron time-of-flight spectrometer
Journal Article
·
Mon Nov 30 23:00:00 EST 1959
· Nuclear Instruments and Methods
·
OSTI ID:4168469