ELECTRON-OPTICAL CONDITIONS AT VENETIAN BLIND TYPE DYNODES AND THEIR EFFECTS IN PHOTOMULTIPLIERS

Journal Article · · Brit. J. Appl. Phys.
Venetian blind type dynodes were investigated to determine their suitability for use in electron-optically efficient photomultipliers for photometry. This was accomplished by means of the electrolytic trough. It was concluded that the nuclear-spectrometric resolution could probably be improved from a half-width of 7.5% to one of 6% or less if a secondary emission system were used that was more ideal than the blind-type dynode system; and that Venetian blind type multipliers are of no use when measurements calling for a short time rise are involved. (L.N.N.)
Research Organization:
VEB Carl Zeiss Jena, Jena, Ger.
Sponsoring Organization:
USDOE
NSA Number:
NSA-15-030867
OSTI ID:
4840827
Journal Information:
Brit. J. Appl. Phys., Journal Name: Brit. J. Appl. Phys. Vol. Vol: 12
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

A VENETIAN BLIND TYPE DYNODE FOR CHANNELLED MULTIPLIERS WITH FAST TIME RESPONSE
Journal Article · Mon Oct 01 00:00:00 EDT 1962 · J. Sci. Instr. · OSTI ID:4729314

A simple method to improve the spatial uniformity of venetian-blind photomultiplier tubes
Journal Article · Sat Jun 01 00:00:00 EDT 1996 · IEEE Transactions on Nuclear Science · OSTI ID:277665

Tests of 5-inch Venetian-blind-type photomultiplier tubes. [For lead glass Cherenkov counters]
Technical Report · Mon Jan 31 23:00:00 EST 1977 · OSTI ID:7312828