Tests of 5-inch Venetian-blind-type photomultiplier tubes. [For lead glass Cherenkov counters]

Technical Report ·
DOI:https://doi.org/10.2172/7312828· OSTI ID:7312828

Test results are described on three inexpensive 5-inch photomultiplier tubes of Venetian-blind construction to be used for collection of Cherenkov light produced by electromagnetic showers in lead glass. Parameters evaluated include photoelectron collection efficiency, pulse-height resolution, amplitude and rate stability, and linearity.

Research Organization:
Los Alamos Scientific Lab., NM (USA)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
7312828
Report Number(s):
LA-6441-MS
Country of Publication:
United States
Language:
English