P-102 ION CHAMBER IRRADIATION IN THE MTR
Technical Report
·
OSTI ID:4840354
A summary is given of tests on the P-102 type ion chambers in the MTR in December, 1958. The chambers tested gave consistent ion chamber type characteristic curves. The leakage current to ground was also investigated. The characteristic curves obtained in the tests are presented. The test was marred by the uncompensated ion chamber developing an internal short circuit during the early part of the test. (auth)
- Research Organization:
- General Electric Co. Aircraft Nuclear Propulsion Dept., Idaho Falls, Idaho
- DOE Contract Number:
- AT(11-1)-171
- NSA Number:
- NSA-16-019069
- OSTI ID:
- 4840354
- Report Number(s):
- DC-59-2-721
- Country of Publication:
- United States
- Language:
- English