OPERATION AND PERFORMANCE OF TEMPERATURE-CONTROL CIRCUIT PROJECT 102, CONTROL SYSTEM
Technical Report
·
OSTI ID:4795442
>A report on the theory of operation, design, calibration and test, and the performance of a temperature-control circuit for project 102 is presented. The various components are discussed and typical circuit data are presented along with schematic drawings, sketches, and photographs. Tests of transient response and steady-state accuracy of the temperature-control circuit, operated in connection with both the control system mockup and the final manufactured system, gave satisfactory results. (auth)
- Research Organization:
- General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
- DOE Contract Number:
- AT(11-1)-171
- NSA Number:
- NSA-16-014226
- OSTI ID:
- 4795442
- Report Number(s):
- DC-58-8-231
- Country of Publication:
- United States
- Language:
- English