CORROSION INVESTIGATION OF HyMu-80 AND INOR-8 UNDER HYDROFLUORINATION CONDITIONS DURING DISSOLUTION OF ZIRCALOY-2
Technical Report
·
OSTI ID:4805034
An experiment was run to determine the durability of HyMu-80 along with INOR-8, under hydrofiuorinator conditions, in a molten salt bath of NaF- LiF- BeF/ sub 2/ at 650 deg C while Zircaloy-2 was being dissolved. The only visible evidence of attack was on those specimens extending through the liquid-vapor interface. These samples were raised with the interface as the zircaloy-2 was added. ln this area, there was severe necking-down of all specimens. In general, the HyMu-80 specimens were as durable as the INOR-8 pieces or even more durable. (M.C.G.)
- Research Organization:
- Battelle Memorial Inst., Columbus, Ohio
- DOE Contract Number:
- W-7405-ENG-92
- NSA Number:
- NSA-16-005665
- OSTI ID:
- 4805034
- Report Number(s):
- BMI-X-184
- Country of Publication:
- United States
- Language:
- English
Similar Records
CORROSION RESISTANCE OF NICKEL-BASE ALLOYS IN A NaF-LiF-BeF$sub 2$-ZrF$sub 4$- MIXTURE UNDER HYDROFLUORINATOR CONDITIONS AT 500 C, WITH AND WITHOUT ZIRCALOY-2 DISSOLVING. PART II
CORROSION RESISTANCE OF EXPERIMENTAL NICKEL-BASE ALLOYS UNDER HYDROFLUORINATOR CONDITIONS
THE CORROSION OF 79-4 (HyMu80) AND INOR-8 RODS IN ORNL SINGLE VESSEL STUDIES
Technical Report
·
Fri Aug 23 00:00:00 EDT 1963
·
OSTI ID:4651995
CORROSION RESISTANCE OF EXPERIMENTAL NICKEL-BASE ALLOYS UNDER HYDROFLUORINATOR CONDITIONS
Technical Report
·
Fri Nov 30 23:00:00 EST 1962
·
OSTI ID:4735535
THE CORROSION OF 79-4 (HyMu80) AND INOR-8 RODS IN ORNL SINGLE VESSEL STUDIES
Technical Report
·
Thu Dec 26 23:00:00 EST 1963
·
OSTI ID:4083430