FORCED CONVECTION LIQUID METAL INPILE LOOP LIQUID METAL PRESSURE DROP CALCULATIONS

Technical Report ·
OSTI ID:4800103
Calculation method and results on pressure drop are reported through the liquid metal flow circuit as a function of experiment geometry in the PW-19 in- pile-loop. A summary is presented of calculated pressure losses in the loop, starting at the pump diffuser discharge and proceeding around to the pump intake. (J.R.D.)
Research Organization:
Pratt and Whitney Aircraft Div., United Aircraft Corp. Connecticut Aircraft Nuclear Engine Lab., Middletown
DOE Contract Number:
AT(11-1)-229
NSA Number:
NSA-16-013212
OSTI ID:
4800103
Report Number(s):
TIM-483
Country of Publication:
United States
Language:
English