FORCED CONVECTION LIQUID METAL INPILE LOOP LIQUID METAL PRESSURE DROP CALCULATIONS
Technical Report
·
OSTI ID:4800103
Calculation method and results on pressure drop are reported through the liquid metal flow circuit as a function of experiment geometry in the PW-19 in- pile-loop. A summary is presented of calculated pressure losses in the loop, starting at the pump diffuser discharge and proceeding around to the pump intake. (J.R.D.)
- Research Organization:
- Pratt and Whitney Aircraft Div., United Aircraft Corp. Connecticut Aircraft Nuclear Engine Lab., Middletown
- DOE Contract Number:
- AT(11-1)-229
- NSA Number:
- NSA-16-013212
- OSTI ID:
- 4800103
- Report Number(s):
- TIM-483
- Country of Publication:
- United States
- Language:
- English
Similar Records
FORCED CONVECTION LIQUID METAL IMPILE LOOP HYDRODYMNAMIC TEST OF THE LIQUID METAL CIRCIUT
NAK PRESSURE DROP CALCULATIONS FOR THE PRATT & WHITNEY FORCED CONVECTION LIQUID METAL INPILE LOOP, PW-19 INCORPORATING THE MARK II CERAMIC TEST SPECIMEN
FORCED CONVECTION LIQUID METAL INPILE LOOP HYDRODYNAMIC TEST OF THE LIQUID CIRCUIT
Technical Report
·
Sun Nov 30 23:00:00 EST 1958
·
OSTI ID:4833708
NAK PRESSURE DROP CALCULATIONS FOR THE PRATT & WHITNEY FORCED CONVECTION LIQUID METAL INPILE LOOP, PW-19 INCORPORATING THE MARK II CERAMIC TEST SPECIMEN
Technical Report
·
Mon Apr 13 23:00:00 EST 1959
·
OSTI ID:4786690
FORCED CONVECTION LIQUID METAL INPILE LOOP HYDRODYNAMIC TEST OF THE LIQUID CIRCUIT
Technical Report
·
Sun Mar 29 23:00:00 EST 1959
·
OSTI ID:4794145