Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

INDUCED THERMAL ERROR FOR THERMOCOUPLES ATTACHED TO THIN PLATES

Technical Report ·
OSTI ID:4793202
An analytical procedure was developed for determining the induced thermal error for a number of configurations of thermocouples attached to thin plates. Generalized plots for quick estimates of induced error are provided for several special cases. Included also are numerous examples to demonstrate the various error prediction methods. (auth)
Research Organization:
General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
DOE Contract Number:
AT(11-1)-171
NSA Number:
NSA-16-010181
OSTI ID:
4793202
Report Number(s):
DC-60-5-45
Country of Publication:
United States
Language:
English

Similar Records

Measurement errors for thermocouples attached to thin plates: Application to heat flux measurement devices
Conference · Sat Dec 31 23:00:00 EST 1988 · OSTI ID:5886500

THERMOCOUPLE ATTACHMENT FOR THE INITIAL EOCR CORE
Technical Report · Wed Feb 13 23:00:00 EST 1963 · OSTI ID:4741372

Intrinsic thermocouple measurement errors
Conference · Tue Dec 31 23:00:00 EST 1974 · OSTI ID:7345227