INDUCED THERMAL ERROR FOR THERMOCOUPLES ATTACHED TO THIN PLATES
Technical Report
·
OSTI ID:4793202
An analytical procedure was developed for determining the induced thermal error for a number of configurations of thermocouples attached to thin plates. Generalized plots for quick estimates of induced error are provided for several special cases. Included also are numerous examples to demonstrate the various error prediction methods. (auth)