CaSO$sub 4$(Mn) THERMOLUMINESCENCE DOSIMETERS FOR SMALL DOSES OF GAMMA RADIATION

Journal Article · · Rev. Sci. Instr.
DOI:https://doi.org/10.1063/1.1717715· OSTI ID:4764551
The thermoluminescence dosimeter offers a cheap means of measuring gamma doses as small as 50 mu r. The CaSO/sub 4/(Mn) is prepared according to Watanabe, and the phosphor powder, mixed with silicon resin, is painted on a strip of Kanthal. For the read-out, the dosimeter is heated by a-c through the Kanthal; the read-out temperature should be kept as low as possible. Random errors are discussed. (D.L.C.)
Research Organization:
Aktiebolaget Atomenergi, Studsvik, Sweden
Sponsoring Organization:
USDOE
NSA Number:
NSA-17-003342
OSTI ID:
4764551
Journal Information:
Rev. Sci. Instr., Journal Name: Rev. Sci. Instr. Vol. Vol: 33
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

THE PROPERTIES OF CaSO$sub 4$: Mn THERMOLUMINESCENCE DOSIMETERS
Technical Report · Sat Jun 01 00:00:00 EDT 1963 · OSTI ID:4694746

MEASUREMENTS OF SMALL EXPOSURES OF GAMMA RADIATION WITH CaSO$sub 4$:Mn RADIOTHERMOLUMINESCENCE
Technical Report · Thu Aug 01 00:00:00 EDT 1963 · OSTI ID:4652749

THERMOLUMINESCENT DOSIMETER