MAGNETIC FIELD SPARK CHAMBERS
Technical Report
·
OSTI ID:4762172
Work was carried out to develop magnetic field spark chambers of high resolution. Initial tests were made with a 2-gap, variable spacing, variable pressure spark chamber filled successively with Ne, Ar, He, and H. A 128-gap chamber with thin plates and 3 mm spacing, having a volume of 30 x 30 x 60 cm, was built. Each plate consists of two 0.025 mm sheets of Al supported on 1.5 mm thick frames of epoxy fiberglass. The chamber drive system consists of a hard- tube trigger which fires a 3-electrode pressurized-air spark-gap. This gap then drives 8 other identical gaps, each of which has eight output cables. These go to simple ferrite-core cable-adding transformers. (M.C.G.)
- Research Organization:
- Princeton-Pennsylvania Accelerator, Princeton, N.J.
- NSA Number:
- NSA-16-031824
- OSTI ID:
- 4762172
- Report Number(s):
- PPAD-455 E
- Country of Publication:
- United States
- Language:
- English