On the accuracy of watt-hour meters in nonsinusoidal environment

Conference ·
OSTI ID:427917
 [1]
  1. Kuwait Univ. (Kuwait). Electrical and Computer Engineering Dept.
This paper deals with the accuracy of induction type watt hour meter operating with harmonic polluted voltage and current waveforms. It starts with the derivation of the registration error resulting from the inherent meter characteristic that exists even for pure sinusoidal voltage and current signals, as well as the error component due to the harmonic content in their time waveforms. A generalized approach is presented allowing for the simultaneous presence of harmonics in both voltage and current. The error is given as a function of three main parameters: the current harmonic distortions HD{sub i}, the voltage harmonic content HD{sub v} and finally the fundamental current. The derived model allows investigating the contribution of each of these parameters to the meter registration error. The effect of both harmonic distortion factors HD{sub i} and HD{sub v} as well as the fundamental current and its displacement factor is illustrated using typical three-dimensional plots. Applying curve fitting techniques, two important approximate relations could be found: The first gives the registration error under pure sinusoidal current and voltage conditions in terms of the peak fundamental current. The resulting equation is insensitive to the current displacement factor. The second relation gives the meter registration error as a function of both distortion factors HD{sub i} and HD{sub v}. The validity of the approximate equation over the entire range of distortion factors is demonstrated.
OSTI ID:
427917
Report Number(s):
CONF-9510203--
Country of Publication:
United States
Language:
English

Similar Records

Harmonic analysis of induction watthour meter performance
Journal Article · Thu Jan 31 23:00:00 EST 1985 · IEEE Trans. Power Appar. Syst.; (United States) · OSTI ID:6253634

Watthour meter accuracy under controlled unbalanced harmonic voltage and current conditions
Journal Article · Sun Dec 31 23:00:00 EST 1995 · IEEE Transactions on Power Delivery · OSTI ID:218286

Induction varhour and solid-state varhour meters performances on nonlinear loads
Journal Article · Mon Oct 01 00:00:00 EDT 1990 · IEEE Transactions on Power Delivery (Institute of Electrical and Electronics Engineers); (USA) · OSTI ID:6208346