MINIATURE BOILER TEST--NAK INJECTION (NO. 1). Memo Report 124

Technical Report ·
OSTI ID:4273506
A test was run to determine the effect of a leak of third fluid NaK into an area of a simulated water side nozzle where temperature measurements have indicated that steam is present. This simulated nozzle was built of type 347 stainless steel. Approximately 1 lb of NaK was injected with nitrogen pressure 600 psig over a period of 11 min through a prepared leak. Within a minute after the NaK injection started, thermocouples located on the outer surface of the boiler in the immediate area of the injection went from 925 deg F to beyond the 1200 deg F scale of the instrument. The boiler was operated for ~20 hr after the NaK was injected without any indication of a failure, after which the unit was secured, allowed to cool, and the insulation removed. A pressure test of 125 psig revealed several cracks in the shell (water side), and evidence of NaK was also found in the insulation indicating that leaks occurred during the NaK injection. (auth)
Research Organization:
Mine Safety Appliances Co., Callery, Penna.
NSA Number:
NSA-13-011859
OSTI ID:
4273506
Report Number(s):
NP-7430
Country of Publication:
United States
Language:
English

Similar Records

MINIATURE BOILER TEST--NaK INJECTION (NO. 2). Memo Report 125
Technical Report · Thu Jan 31 23:00:00 EST 1957 · OSTI ID:4274745

MINIATURE BOILER TEST. Memo Report 123
Technical Report · Mon Dec 31 23:00:00 EST 1956 · OSTI ID:4245444

TEST OF THIRD FLUID VALVE FOR USE WITH NaK. Memo Report 84
Technical Report · Tue Jun 14 00:00:00 EDT 1955 · OSTI ID:4274827