TEST OF THIRD FLUID VALVE FOR USE WITH NaK. Memo Report 84
Technical Report
·
OSTI ID:4274827
A 1/4 in. bellows Hoke'' valve designed for use with mercury in the third fluid system of Mark B was tested and proved satisfactory for use with NaK- 78. The valve was found to be leak tight on the valve body and across the seat by mass spectrometer tests given after each series of the major tests listed: valve open, 600 psig nitrogen pressure over NaK at 70, 125, 250, 375. and 500 deg F for 1 hr each on valve body; and, 100 cyclic tests of opening and closing with NaK at room temperature at 40 psig, followed by 600 psig across the seat for 1 hr. (auth)
- Research Organization:
- Mine Safety Appliances Co., Callery, Penna.
- NSA Number:
- NSA-13-011847
- OSTI ID:
- 4274827
- Report Number(s):
- NP-7404
- Country of Publication:
- United States
- Language:
- English
Similar Records
MINIATURE BOILER TEST--NAK INJECTION (NO. 1). Memo Report 124
PLUGGING LEAKS BETWEEN WATER AND THIRD FLUID SYSTEM (NaK). Memo Report 117
TEST OF A 1 INCH COMBINED VALVE CONNECT AND DISCONNECT. Memo Report 95
Technical Report
·
Tue Jan 15 23:00:00 EST 1957
·
OSTI ID:4273506
PLUGGING LEAKS BETWEEN WATER AND THIRD FLUID SYSTEM (NaK). Memo Report 117
Technical Report
·
Tue Aug 21 00:00:00 EDT 1956
·
OSTI ID:4259428
TEST OF A 1 INCH COMBINED VALVE CONNECT AND DISCONNECT. Memo Report 95
Technical Report
·
Sun Nov 20 23:00:00 EST 1955
·
OSTI ID:4273546