TRANSDUCERS FOR STRAIN MEASUREMENT IN INTENSE RADIATION FIELDS
Technical Report
·
OSTI ID:4252670
Paper No. 507 Presented at The Society for Experimental Stress Analysis STAMeeting!, Cleveland, May 14A need exists for transducers capable of accurately measuring strain in the presence of gamma and neutron radiations. A series of experiments is described in which high temperature type strain gages were exposed to typical reactor radiations. The results indicate that foil transducers bonded to metal specimens with ceramic cements operate satisfactorily for limited integrated neutron fluxes. ( auth)