CALIBRATION OF STRAIN GAGES AT HIGH TEMPERATURE: SECOND REPORT
Technical Report
·
OSTI ID:4641001
Wire grid, single-filament, and foil (including one cemented to a weldable coupon) strain gages mounted on R235 tubing were tested in tension at 800, 950, and 1100 deg F. Erratic operation and/or failure on test eliminated the weldable, wire grid, and single filament gages for use on R-235 at these temperatures. The other foil gages were somewhat consistent. The ratio of average optical to average ceramic cemented gage reading at room temperature was determined. Strain due to temperature alone had no consistent relation to the results obtained at temperature under tension. The errors on the pull test were large and covered broad bands. (D.C.W.)
- Research Organization:
- California. Univ., Livermore. Lawrence Radiation Lab.
- DOE Contract Number:
- W-7405-ENG-48
- NSA Number:
- NSA-17-036124
- OSTI ID:
- 4641001
- Report Number(s):
- UCRL-7276; CONF-147-1
- Country of Publication:
- United States
- Language:
- English
Similar Records
DEVELOPMENT OF HIGH-TEMPERATURE STRAIN GAGES. National Bureau of Standards Monograph No. 26
Evaluation of the Kulite semiconductor strain gage, model M(6) EP-120-500W, spotwelded to P-110 pipe material
Evaluation of the Kulite semiconductor strain gage, model M(6) EP-120-500W, spotwelded to P-110 pipe material. [Simulated Nevada Test Site conditions]
Technical Report
·
Thu Mar 16 23:00:00 EST 1961
·
OSTI ID:4034285
Evaluation of the Kulite semiconductor strain gage, model M(6) EP-120-500W, spotwelded to P-110 pipe material
Technical Report
·
Wed Jun 01 00:00:00 EDT 1977
·
OSTI ID:7104072
Evaluation of the Kulite semiconductor strain gage, model M(6) EP-120-500W, spotwelded to P-110 pipe material. [Simulated Nevada Test Site conditions]
Technical Report
·
Tue Jul 13 00:00:00 EDT 1976
·
OSTI ID:7148117