7GeV PROTON SYNCHROTRON SOME EFFECTS OF POWER SUPPLY RIPPLE VOLTAGE
Technical Report
·
OSTI ID:4240198
The output voltage or the 7-Bev proton synchrotron power supply will contain 600 c/s and higher frequency ripple components. The effects of this ripple on synchrotron operation are discussed. It is shown that efficient ripple filtering devices will be required, particularly for satisfactory flat-top pulse operation. (auth)