7 GeV PROTON SYNCHROTRON OPTIMUM PHASING OF THE MAGNET POWER SUPPLY
Technical Report
·
OSTI ID:4231316
Perturbations or the magnetic field in the 7-Bev proton synchrotron may result from power supply ripple voltages in a variety of ways. The likely magnitudes of the various perturbations are calculated, and the best choice of power supply circuit from this viewpoint is discussed. A particular 24-phase arrangement is shown to be advantageous. (auth)
- Research Organization:
- United Kingdom Atomic Energy Authority. Research Group. Atomic Energy Research Establishment, Harwell, Berks, England
- NSA Number:
- NSA-13-018185
- OSTI ID:
- 4231316
- Report Number(s):
- AERE-A/R-2846
- Country of Publication:
- United Kingdom
- Language:
- English
Similar Records
7GeV PROTON SYNCHROTRON SOME EFFECTS OF POWER SUPPLY RIPPLE VOLTAGE
7 GEV PROTON SYNCHROTRON MAGNET POWER SUPPLY VOLTAGE WAVEFORMS
MAGNET POWER SUPPLY FOR THE 7 Gev PROTON SYNCHROTRON NIMROD. PART 2. ROTATING MACHINES
Technical Report
·
Tue Mar 31 23:00:00 EST 1959
·
OSTI ID:4240198
7 GEV PROTON SYNCHROTRON MAGNET POWER SUPPLY VOLTAGE WAVEFORMS
Technical Report
·
Sat Oct 31 23:00:00 EST 1959
·
OSTI ID:4197795
MAGNET POWER SUPPLY FOR THE 7 Gev PROTON SYNCHROTRON NIMROD. PART 2. ROTATING MACHINES
Journal Article
·
Thu Feb 28 23:00:00 EST 1963
· Proc. Inst. Elec. Engrs., (London)
·
OSTI ID:4703209