BETA FIELD DOSE RATE DETERMINATION WITH THE C.P. DOSE RATE METER
Technical Report
·
OSTI ID:4196559
An experimental method of field dose rate determination using dose rate meters was developed. The method utilizes the factor obtained by forming the ratio of the totaal integrated dose rate obtained with the forward axis of the chamber intersecting the center of the incremental source to the total integrated dose obtained with the forward axis of the chamber intersecting the center of the integrated source. Data were taken and analyzed in accordance with this method for the C.P. dose rate meter. Correction factors were determined for beta field determination with the C.P. dose rate meter. (C.H.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- W-31-109-ENG-52
- NSA Number:
- NSA-14-000454
- OSTI ID:
- 4196559
- Report Number(s):
- HW-40809
- Country of Publication:
- United States
- Language:
- English
Similar Records
BETA FIELD DOSE RATE DETERMINATION FOR ANGULAR RESPONSE WITH THE JUNO DOSE RATE METER
BETA FIELD DOSE RATE DETERMINATION FOR ANGULAR RESPONSE WITH THE SOUP BOWL DOSE RATE METER
Field tests of a portable tissue equivalent survey meter for monitoring mixed beta/gamma radiation fields
Technical Report
·
Thu Oct 15 00:00:00 EDT 1959
·
OSTI ID:4237531
BETA FIELD DOSE RATE DETERMINATION FOR ANGULAR RESPONSE WITH THE SOUP BOWL DOSE RATE METER
Technical Report
·
Thu Sep 12 00:00:00 EDT 1957
·
OSTI ID:4816387
Field tests of a portable tissue equivalent survey meter for monitoring mixed beta/gamma radiation fields
Technical Report
·
Thu May 01 00:00:00 EDT 1986
·
OSTI ID:5746438