OPERATING CHARACTERISTICS OF IONIZATION CHAMBERS FILLED WITH LIQUID HEXANE (in French)
Journal Article
·
· Compt. rend.
OSTI ID:4188865
Measurements were made, at laboratory temperature, of the current flowing in liquid hexane-filled ionization chambers during alpha and gamma irradiation. The Jaffe theory applies when the electric field is below 12,000 v/ cm. Above this an amplification effect is produced in the detector analogous to that for gas-filled chambers. (tr-auth)
- Research Organization:
- Centre de Physique Nucleaire, Toulouse, France
- NSA Number:
- NSA-14-005354
- OSTI ID:
- 4188865
- Journal Information:
- Compt. rend., Journal Name: Compt. rend. Vol. Vol: 249
- Country of Publication:
- Country unknown/Code not available
- Language:
- French