EFFECT OF GASEOUS IMPURITIES ON BF$sub 3$ PROPORTIONAL COUNTERS

Journal Article · · Rev. Sci. Instr.
DOI:https://doi.org/10.1063/1.1931243· OSTI ID:4168704

The effects which SiF/sub 4/, SO/sub 2/, and SF/sub 6/ have on the plateau and the pulse size distribution of a proportional counter were investigated. SiF/sub 4/ was tested at three pressures, 30, 45, and 60 cm, of BF/ sub 3/ and its effect was found to be independent of the counter pressure for the range of value considered. From the variation in the plateau, the attachment probability for SiF/sub 4/ was calculated to be h= 1.485 x 10/sup -5/ and its cross section for attachment to be sigma /sub a/ = 5.12 x 10/sup -20/ cm/sup 2/. The amount of these gasea permitted, without the counter being affected beyond the limits of tolerance which are set up, were found to be 0.04% for SiF/sub 4/, 0.01% for SO/sub 2/, and 2.0 x 10/sup -6/% for SF/sub 6/. (auth)

Research Organization:
New York Univ., New York
Sponsoring Organization:
USDOE
NSA Number:
NSA-14-014924
OSTI ID:
4168704
Journal Information:
Rev. Sci. Instr., Journal Name: Rev. Sci. Instr. Vol. Vol: 31
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

EFFECT OF GASEOUS IMPURITIES IN BF$sub 3$ PROPORTIONAL COUNTERS
Technical Report · Sun Nov 30 23:00:00 EST 1958 · OSTI ID:4274198

PLATEAU SLOPES AND PULSE CHARACTERISTICS OF LARGE, HIGH-PRESSURE BF$sub 3$ COUNTERS
Technical Report · Wed Jul 01 00:00:00 EDT 1959 · OSTI ID:4211618

RESEARCH ON BF$sub 3$ PROPORTIONAL COUNTERS
Journal Article · Thu Mar 31 23:00:00 EST 1960 · Kernenergie (East Germany) · OSTI ID:4138699