PRODUCTION OF I$sup 132$ AND ITS USE IN 3-HOUR THYROID UPTAKE TEST

Journal Article · · Polski Tygod. Lekar.
OSTI ID:4144886
A method for obtaining I/sup 132/ from Te/sup 132/ is described and its effectiveness in testing thyroid uptake in normal individuals and patients suffering from various thyroid diseases was studied. It was concluded that the 3- hour I/sup 132/ uptake test is most reliable, and its diagnostic value equal, or better than the T/sub 24/I/sup 131/ test. (OTS)