THE HOT DUCTILITY OF INCONEL BP-85 WELD DEPOSITS
Technical Report
·
OSTI ID:4135660
In onder to evaluate the fissure tendency of a covered Inconel BP-85 welding electrode, the ductility of weld deposits from this electrode was studied at high temperatures. The results indicate that Inconel BP-85 welds have good hot ductility but lose their ductility completely at 2150 deg F, while wrought Inconel keeps its ductility up to 2400 deg F. (D.L.C.)