DC BRIDGE FOR NPR HORIZONTAL ROD COUNTING
Technical Report
·
OSTI ID:4114687
The horizontal rod counting circuitry of the NPR ball safety system backup for horizontal rods uses a d-c bridge network. The principles of a counting bridge are presented, together with the general bridge equations and the design criteria used. Bridge component selection, optimization, and tolerances are then summarized; and the physical and operating characteristics of the two types of bridge counting circuits used are discussed. (D.C.W.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-18-009645
- OSTI ID:
- 4114687
- Report Number(s):
- HW-61240
- Country of Publication:
- United States
- Language:
- English