Xenon Transient Tests: Core I, Seed 2, 149.8 EFPH: Section 1 - Test Results T-612081

Technical Report ·
DOI:https://doi.org/10.2172/4091338· OSTI ID:4091338
A test was made to determine if there is sufficient excess reactivity in the core to override a peak xenon transient and to obtain data for rod worth calculations. After 149.8 EFPH's of plant operation on seed 2, there was sufficient excess reactivity to override peak xenon. Criticality during peak xenon was maintained with group III and group IV rods inserted, group I rods withdrawn to approximately 69 in., and group II rods withdrawn to approximately 29 in. The override of peak xenon occurred 8 hours and 45 min after shutdown.
Research Organization:
Duquesne Light Co., Shippingport, PA (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA), Nuclear Criticality Safety Program (NCSP); US Atomic Energy Commission (AEC)
NSA Number:
NSA-15-010509
OSTI ID:
4091338
Report Number(s):
DLCS-1560107
Country of Publication:
United States
Language:
English