Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Hardware design and implementation of the closed-orbit feedback system at APS

Conference ·
OSTI ID:379075
The Advanced Photon Source (APS) storage ring will utilize a closed-orbit feedback system in order to produce a more stable beam. The specified orbit measurement resolution is 25 microns for global feedback and 1 micron for local feedback. The system will sample at 4 kHz and provide a correction bandwidth of 100 Hz. At this bandwidth, standard rf BPMs will provide a resolution of 0.7 micron, while specialized miniature BPMs positioned on either side of the insertion devices for local feedback will provide a resolution of 0.2 micron (1). The measured BPM noise floor for standard BPMs is 0.06 micron per root hertz mA. Such a system has been designed, simulated, and tested on a small scale (2). This paper covers the actual hardware design and layout of the entire closed-loop system. This includes commercial hardware components, in addition to many components designed and built in-house. The paper will investigate the large-scale workings of all these devices, as well as an overall view of each piece of hardware used.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
379075
Report Number(s):
ANL/ASD/CP--89623; CONF-9605173--14; ON: DE96015081
Country of Publication:
United States
Language:
English

Similar Records

Hardware design and implementation of the closed-orbit feedback system at APS
Journal Article · Tue Dec 31 23:00:00 EST 1996 · AIP Conference Proceedings · OSTI ID:526816

FIRST BEAM TESTS OF THE APS MBA UPGRADE ORBIT FEEDBACK CONTROLLER
Conference · Sat Mar 25 00:00:00 EDT 2017 · OSTI ID:1393938

Commissioning results of the APS storage ring rf beam position monitors
Technical Report · Mon Jul 01 00:00:00 EDT 1996 · OSTI ID:270783