Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Results of the September 1997 DOE/EPA demonstration of multimetal continuous emission monitoring technologies

Journal Article · · Waste Management
;  [1];  [2];  [3];  [4];  [5]
  1. Environmental Protection Agency, Research Triangle Park, NC (United States). National Risk Management Research Lab.
  2. Sky+, Inc., Oakland, CA (United States)
  3. Ames Lab., IA (United States)
  4. Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States)
  5. Westinghouse Savannah River, Aiken, SC (United States)

In September 1997, the US Department of Energy (DOE) and US Environmental Protection Agency (EPA) co-sponsored a demonstration of several multimetal continuous emission monitors (CEMs). The demonstration, performed at the EPA National Risk Management Research Laboratory, Air Pollution Prevention and Control Division`s combustion laboratory in Research Triangle Park, NC, involved the side-by-side testing of seven multimetal CEMs at various stages of commercialization. A series of tests were performed to compare results from the multimetal CEMs to Method 0060, the EPA reference method (RM) for metals emissions measurements, using the relative accuracy test audit (RATA) protocol. The EPA operated the test facility and performed the RM sampling, and each multimetal CEM was operated by the instrument`s respective developer. To accomplish these tests, an aqueous solution of six toxic metals (arsenic, beryllium, cadmium, chromium, lead, and mercury), along with flyash from a coal-fired utility boiler, was injected into the afterburner of the EPAs rotary kiln incinerator simulator facility to generate a combustor flue gas with realistic post-flue gas cleaning system particulate loadings and target metals concentrations of approximately 15 and 75 {micro}g/m{sup 3}, which constituted the low and high concentration test conditions. The multimetal CEMs that participated in the test included two laser-induced breakdown spectroscopy (LIBS) systems, two inductively coupled plasma (ICP) systems, a spark-induced breakdown spectroscopy (SIBS) system, a hazardous element sampling train with X-ray fluorescence (HEST/XRF), and a microwave plasma system. Ten RM-CEM sample pairs were taken at both the low and high concentration test conditions, and the relative accuracies of the multimetal CEMs were calculated. This test provided performance data that will be used to assess the current state of the art in multimetal CEMs.

OSTI ID:
347627
Report Number(s):
CONF-980513--
Journal Information:
Waste Management, Journal Name: Waste Management Journal Issue: 6-8 Vol. 18; ISSN WAMAE2; ISSN 0956-053X
Country of Publication:
United States
Language:
English

Similar Records

Performance testing of multi-metal continuous emissions monitors
Technical Report · Sun Nov 16 23:00:00 EST 1997 · OSTI ID:587875

Demonstration of SPICAP multimetals CEM
Conference · Tue Dec 30 23:00:00 EST 1997 · OSTI ID:353593

Laser-induced breakdown spectrometry as a multimetal continuous-emission monitor
Journal Article · Sun Feb 28 23:00:00 EST 1999 · Applied Optics · OSTI ID:365850