CEBAF cryogenic system

Conference ·
OSTI ID:283779

The CEBAF cryogenic system consists of 3 refrigeration systems: Cryogenic Test Facility (CTF), Central Helium Liquefier (CHL), and End Station Refrigerator (ESR). CHL is the main cryogenic system for CEBAF, consisting of a 4.8 kW, 2.0 K refrigerator and transfer line system to supply 2.0 K and 12 kW of 50 K shield refrigeration for the Linac cavity cryostats and 10 g/s of liquid for the end stations. This paper describes the 9-year effort to commission these systems, concentrating on CHL with the cold compressors. The cold compressors are a cold vacuum pump with an inlet temperature of 3 K which use magnetic bearings, thereby eliminating the possibility of air leaks into the subatmospheric He.

Research Organization:
CEBAF, Newport News, VA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
283779
Report Number(s):
DOE/ER/40150--358; CEBAF-PR--95-040; CONF-950512--377; ON: DE96013340
Country of Publication:
United States
Language:
English

Similar Records

Procurement and commissioning of the CHL refrigerator at CEBAF
Technical Report · Thu Aug 01 00:00:00 EDT 1996 · OSTI ID:270822

Procurement and commissioning of the CHL refrigerator at CEBAF
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:416697

The CEBAF cryogenic system: Continuous Electron Beam Accelerator Facility
Technical Report · Sat Dec 31 23:00:00 EST 1988 · OSTI ID:6360179