The CEBAF cryogenic system: Continuous Electron Beam Accelerator Facility

Technical Report ·
DOI:https://doi.org/10.2172/6360179· OSTI ID:6360179
The CEBAF superconducting linear accelerator incorporates cryogenic refrigeration equipment at three locations within the site: the Central Helium Liquefier, located in the center of the accelerator; the experimental end station refrigerator; and the test laboratory refrigerator located in the Cryogenic Test Facility (CTF) adjacent to the test laboratory. The CEBAF cryogenic system will provide 2K refrigeration to the linacs of the accelerator and test laboratory and 4.5K refrigeration for the end station experimental halls. The Central Helium Liquefier and the test laboratory systems will produce 45K supercritical gaseous helium for shield refrigeration. Liquid nitrogen shields will also be incorporated in the test laboratory and end stations. 6 refs., 5 figs.
Research Organization:
Southeastern Universities Research Association, Newport News, VA (USA). Continuous Electron Beam Accelerator Facility
DOE Contract Number:
AC05-84ER40150
OSTI ID:
6360179
Report Number(s):
DOE/ER/40150-65; CEBAF-PR-89-007; ON: DE89010339
Country of Publication: