Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Alloy 400 tube failures by stress corrosion cracking

Technical Report ·
OSTI ID:227013
 [1]
  1. Consolidated Edison Company of New York, Inc., NY (United States)

A feedwater heater with SB163 Alloy 400 (cold drawn - stress relieved) tubing experienced numerous tube failures and was replaced after of 4.5 years. Failures were attributed to Inter Granular Stress Corrosion Cracking (IGSCC) in the roll transition area. An eddy current test method was developed with EPRI NDE Center technical support to detect the cracks in the tubesheet region. Three tubes were pulled for metallurgical examination. Short axial cracks were found on tube inner surface. Measured crack depths were correlated with the eddy current indications. A large number of tubes were plugged. However, the heater continued to deteriorate rapidly. Potential contributors to IGSCC are discussed.

Research Organization:
Electric Power Research Inst., Palo Alto, CA (United States)
OSTI ID:
227013
Report Number(s):
EPRI-TR--105876; CONF-9509192--
Country of Publication:
United States
Language:
English

Similar Records

Stress corrosion cracking of Ni-Cu alloy 400 tubes in feedwater heaters
Conference · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:78283

Analysis of failure modes resulting in stress corrosion cracking of 304N tubing in a high pressure heater desuperheater
Journal Article · Thu Oct 01 00:00:00 EDT 1998 · Journal of Engineering for Gas Turbines and Power · OSTI ID:316157

Analysis of failure modes resulting in stress corrosion cracking of 304N tubing in a high pressure heater desuperheater
Conference · Sat Dec 30 23:00:00 EST 1995 · OSTI ID:207778