Purpose. To evaluate the efficacy and safety of Gunther tulip retrievable vena cava filter (GTF) implantation to prevent pulmonary embolism during intravenously administered thrombolytic and anticoagulation therapy and interventional radiological therapy for occlusive or nonocclusive deep venous thrombosis (DVT) of the lower extremity. Methods. We evaluated placement of 55 GTFs in 42 patients with lower extremity DVT who had undergone various treatments including those utilizing techniques of interventional radiology. Results. Worsening of pulmonary embolism in patients with existing pulmonary embolism or in those without pulmonary embolism at the time of GTF insertion was avoided in all patients. All attempts at implantation of the GTF were safely accomplished. Perforation and migration experienced by one patient was the only complication. Mean period of treatment for DVT under protection from pulmonary embolism by the GTF was 12.7 {+-} 8.3 days (mean {+-} SD, range 4-37 days). We attempted retrieval of GTFs in 18 patients in whom the venous thrombus had disappeared after therapy, and retrieval in one of these 18 cases failed. GTFs were left in the vena cava in 24 patients for permanent use when the DVT was refractory to treatment. Conclusion. The ability of the GTF to protect against pulmonary embolism during treatment of DVT was demonstrated. Safety in both placement and retrieval was clarified. Because replacement with a permanent filter was not required, use of the GTF was convenient when further protection from complicated pulmonary embolism was necessary.

OSTI ID:
21091380
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 28, Issue 4; Other Information: DOI: 10.1007/s00270-004-0108-3; Copyright (c) 2005 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Gunther Tulip Retrievable Inferior Vena Caval Filters: Indications, Efficacy, Retrieval, and Complications
Journal Article · Thu Feb 15 00:00:00 EST 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21091380

Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes
Journal Article · Thu Aug 01 00:00:00 EDT 2013 · Cardiovascular and Interventional Radiology · OSTI ID:21091380

Evaluation of Retrievability of the Gunther Tulip Vena Cava Filter
Journal Article · Sun Apr 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21091380