Title: Evaluation of Retrievability of the Gunther Tulip Vena Cava Filter

Journal Article · · Cardiovascular and Interventional Radiology
; ; ; ; ;  [1]
  1. Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Department of Radiology (Japan)

Purpose. To evaluate the feasibility and safety of withdrawal of a Gunther tulip retrievable vena cava filter (GTF). Methods. Between June 2001 and December 2005, at our institution 86 GTFs were implanted for temporary caval filtration in 59 patients (37 women, 22 men; mean age 59.3 years, range 18-87 years). For GTFs retrieved thereafter, we retrospectively reviewed the following parameters: rate of success in retrieval, degree of trapped thrombus in the filter, and complications during retrieval. Results. Worsening of or new development of pulmonary embolism after filter implantation did not occur in any patient. Of the 86 GTFs implanted, retrieval of 80 was attempted. Among those 80 filters, 77 (96%) were successfully retrieved (with the standard method, n = 72; with the modified method, n = 5) without any complication. The period of implantation of the retrieved filters was 13.4 {+-} 4.2 days. In the 5 filters that were filled to a height of {>=} 1/4 with trapped thrombus, retrieval was performed after attempts were made to decrease trapped thrombi. In addition, a temporary filter or another GTF was temporarily placed at the cephalad level of the GTF during this removal procedure. Conclusion. GTFs can be retrieved in the majority of cases. Even when encountering situations in which the filter could not be removed using the standard method, withdrawal was possible in a high frequency of cases through various trials using modified methods.

OSTI ID:
21091023
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 30, Issue 2; Other Information: DOI: 10.1007/s00270-006-0166-9; Copyright (c) 2007 Springer Science+Business Media, Inc.; www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Gunther Tulip Inferior Vena Cava Filter Placement During Treatment for Deep Venous Thrombosis of the Lower Extremity
Journal Article · Sun May 15 00:00:00 EDT 2005 · Cardiovascular and Interventional Radiology · OSTI ID:21091023

Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes
Journal Article · Thu Aug 01 00:00:00 EDT 2013 · Cardiovascular and Interventional Radiology · OSTI ID:21091023

Gunther Tulip Retrievable Inferior Vena Caval Filters: Indications, Efficacy, Retrieval, and Complications
Journal Article · Thu Feb 15 00:00:00 EST 2007 · Cardiovascular and Interventional Radiology · OSTI ID:21091023