Heparin-Coated Angiographic Catheters: An In Vivo Comparison of Three Coating Methods with Different Heparin Release Profiles
Journal Article
·
· Cardiovascular and Interventional Radiology
- Kwangju Institute of Science and Technology, Department of Materials Science and Engineering (Korea, Republic of)
- Mediplex Co., Commercialization Blg, Research and Development Division (Korea, Republic of)
- Seoul National University Bundang Hospital, Department of Radiology (Korea, Republic of)
- Seoul National University College of Medicine, 28 Yongon-dong, Chongno-gu, Seoul, 110-744, Korea. Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital , Department of Radiology (Korea, Republic of)
We evaluated in vivo anti-thrombogenic effects of three different heparin-coated angiographic catheters with different heparin release profiles. Three different types of heparin-coated 5 French angiographic catheters (rapidly-heparin-releasing, slowly-heparin-releasing, and heparin-adherent catheters) were prepared by coating amphiphilic or hydrophobic heparin derivatives in order to regulate heparin elution. After incubation time of 30 minutes in the arteries of dogs, the amount of thrombus deposition, measured as dry weight, was compared in 10 sets of the three heparin-coated catheters and a non-coated catheter used as control. The surface morphology of catheters after their withdrawal was studied by scanning electron microscopy. The amount of thrombus deposition on the non-coated catheter (374.6 {+-} 11.6 mg, mean {+-} SD) was significantly larger than those on the rapidly-heparin-releasing (52.0 {+-} 12.6), slowly-heparin-releasing (70.4 {+-} 23.1), and heparin-adherent catheters (103.7 {+-} 39.9) (p < 0.001, each). The thrombus weights in the three heparin-coated catheters were not statistically different. The scanning electron microscopy showed crusts on the catheter surface, which were thickest in the non-coated catheters. We concluded that the thrombus formation inside a catheter is significantly decreased if the catheter is treated with any of the three heparin-coating methods used in this study. The in vivo anti-thrombogenic effects of these coating methods are not significantly different despite their different heparin release profiles.
- OSTI ID:
- 21088226
- Journal Information:
- Cardiovascular and Interventional Radiology, Journal Name: Cardiovascular and Interventional Radiology Journal Issue: 5 Vol. 27; ISSN 0174-1551; ISSN CAIRDG
- Country of Publication:
- United States
- Language:
- English
Similar Records
The dynamics of platelet thrombus formation rate, thrombus retention time, and rate of embolization on a control and heparin bonded polyurethane angio-catheter
Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters
In vivo method for the evaluation of catheter thrombogenicity
Journal Article
·
Sun Jul 01 00:00:00 EDT 1990
· ASAIO Transactions (American Society for Artificial Internal Organs); (USA)
·
OSTI ID:6273322
Comparison of Heparin-Coated and Conventional Split-Tip Hemodialysis Catheters
Journal Article
·
Wed Jul 15 00:00:00 EDT 2009
· Cardiovascular and Interventional Radiology
·
OSTI ID:21428489
In vivo method for the evaluation of catheter thrombogenicity
Journal Article
·
Wed Dec 31 23:00:00 EST 1986
· J. Biomed. Mater. Res.; (United States)
·
OSTI ID:6524042