Tank Bottom Corrosion Induced by Anode-Generated Oxygen
Journal Article
·
· Materials Performance
OSTI ID:1784917
- Zerust Oil and Gas, Beachwood, OH (United States)
- Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)
Cathodic protection system using aclose coupled mixed metal oxide (MMO) anode is the corrosion prevention technique for soil-side of the aboveground storage tank (AST) bottoms. MMO anodes generate oxygen at its surfacesdue to water electrolysis at polarized potentials above a threshold; oxygen from the MMO anodes can depolarize the bottoms’polarized potentials. Further, when the tank bottom plate loses contact with the sand pad due to flexing, oxygen can accumulate in the void space and accelerate corrosion. This paper provides information on preventive measures that can be adopted to prevent oxygen concentration corrosion of the AST soil-side bottoms
- Research Organization:
- Savannah River Site (SRS), Aiken, SC (United States); Savannah River National Lab (SRNL), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM)
- Grant/Contract Number:
- AC09-08SR22470
- OSTI ID:
- 1784917
- Report Number(s):
- SRNL--STI-2020-00579
- Journal Information:
- Materials Performance, Journal Name: Materials Performance Journal Issue: 2 Vol. 60; ISSN 0094-1492
- Publisher:
- NACE InternationalCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Application of Vapor Corrosion Inhibitors for Tank Bottom Plate Corrosion Control
Cathodic protection of aboveground storage tank bottoms
Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application
Journal Article
·
Sun Feb 10 23:00:00 EST 2019
· Materials Performance
·
OSTI ID:1542569
Cathodic protection of aboveground storage tank bottoms
Journal Article
·
Fri Dec 31 23:00:00 EST 1993
· Materials Performance; (United States)
·
OSTI ID:5152337
Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application
Conference
·
Tue Jan 23 23:00:00 EST 2024
·
OSTI ID:2322415