Soil-side corrosion of aboveground storage tank (AST) bottoms is a great challenge. ASTs usually include active cathodic protection (CP) systems to mitigate soil-side corrosion of the bottoms. CP systems could fail leading to unprotected tank bottoms, and sometime corrosion could occur even with active CP. A study was conducted to determine efficacy of the vapor corrosion inhibitor (VCI) technology in mitigating corrosion. VCIs were discovered to be effective in mitigating corrosion when recommended dosages are used, and could also be used in combination with impressed current CP systems. Overall, VCI technology was found to be a viable corrosion control measure.
- Research Organization:
- Savannah River National Lab (SRNL), Aiken, SC (United States); Savannah River Site (SRS), Aiken, SC (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Management (EM)
- Grant/Contract Number:
- AC09-08SR22470
- OSTI ID:
- 1542569
- Report Number(s):
- SRNL-STI--2019-00078
- Journal Information:
- Materials Performance, Journal Name: Materials Performance Journal Issue: 3 Vol. 58; ISSN 0094-1492
- Publisher:
- NACE InternationalCopyright Statement
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application
Tank Bottom Corrosion Induced by Anode-Generated Oxygen
Effectiveness of Vapor Corrosion Inhibitors Under Bacterial Activity for Aboveground Storage Tank Application
Conference
·
Tue Jan 23 23:00:00 EST 2024
·
OSTI ID:2322415
Tank Bottom Corrosion Induced by Anode-Generated Oxygen
Journal Article
·
Sun Dec 13 23:00:00 EST 2020
· Materials Performance
·
OSTI ID:1784917
Effectiveness of Vapor Corrosion Inhibitors Under Bacterial Activity for Aboveground Storage Tank Application
Conference
·
Tue Jan 23 23:00:00 EST 2024
·
OSTI ID:2322416