skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Basis document for PFP plutonium nitrate ion exchange process in Room 228A

Technical Report ·
DOI:https://doi.org/10.2172/16903· OSTI ID:16903

The PFP facility currently has approximately 4300 liters of plutonium nitrate solution in storage. This material will be calcined by the Vertical Denigration Calciner (VDC) located in room 230C. However, part of the material needs to be purified to remove constituents that will interfere with the calcination process. An Ion Exchange process using Reillex{trademark} HPQ anion exchange resin was tested by the Plutonium Process Support Laboratories (PPSL) (I). The Ion exchange process is to be installed in glovebox HC-7 in room 228A/234-5Z. The plutonium separated from the interfering constituents will be in a concentrated condition ready to be calcined by the VDC in room 230C. The oxide product of the VDC will be placed into the 2736-Z vaults for long term storage.

Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
16903
Report Number(s):
HNF-SD-CP-OCD-044; ON: DE98059748; BR: EW7040000; ON: DE98059748; BR: EW7040000; TRN: US0111101
Resource Relation:
Other Information: PBD: 23 Apr 1997; Supercedes report DE98059748; PBD: 23 Apr 1997
Country of Publication:
United States
Language:
English