Title: Basis document for PFP plutonium nitrate ion exchange process in Room 228A

Abstract

The PFP facility currently has approximately 4300 liters of plutonium nitrate solution in storage. This material will be calcined by the Vertical Denigration Calciner (VDC) located in room 230C. However, part of the material needs to be purified to remove constituents that will interfere with the calcination process. An Ion Exchange process using Reillex{trademark} HPQ anion exchange resin was tested by the Plutonium Process Support Laboratories (PPSL) (I). The Ion exchange process is to be installed in glovebox HC-7 in room 228A/234-5Z. The plutonium separated from the interfering constituents will be in a concentrated condition ready to be calcined by the VDC in room 230C. The oxide product of the VDC will be placed into the 2736-Z vaults for long term storage.

Authors:
Publication Date:
Sponsoring Org.:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (US)
OSTI Identifier:
16903
Report Number(s):
HNF-SD-CP-OCD-044; ON: DE98059748; BR: EW7040000
ON: DE98059748; BR: EW7040000; TRN: US0111101
DOE Contract Number:
AC06-96RL13200
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 23 Apr 1997; Supercedes report DE98059748; PBD: 23 Apr 1997
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; ION EXCHANGE; PLUTONIUM NITRATES; FUEL REPROCESSING PLANTS; HANFORD RESERVATION; CALCINATION; ION EXCHANGE MATERIALS; MATERIALS TESTING; RADIOACTIVE WASTE PROCESSING

Citation Formats

Risenmay, H.R. Basis document for PFP plutonium nitrate ion exchange process in Room 228A. United States: N. p., 1997. Web. doi:10.2172/16903.
Risenmay, H.R. Basis document for PFP plutonium nitrate ion exchange process in Room 228A. United States. doi:10.2172/16903.
Risenmay, H.R. Wed . "Basis document for PFP plutonium nitrate ion exchange process in Room 228A". United States. doi:10.2172/16903. https://www.osti.gov/servlets/purl/16903.
@article{osti_16903,
title = {Basis document for PFP plutonium nitrate ion exchange process in Room 228A},
author = {Risenmay, H.R.},
abstractNote = {The PFP facility currently has approximately 4300 liters of plutonium nitrate solution in storage. This material will be calcined by the Vertical Denigration Calciner (VDC) located in room 230C. However, part of the material needs to be purified to remove constituents that will interfere with the calcination process. An Ion Exchange process using Reillex{trademark} HPQ anion exchange resin was tested by the Plutonium Process Support Laboratories (PPSL) (I). The Ion exchange process is to be installed in glovebox HC-7 in room 228A/234-5Z. The plutonium separated from the interfering constituents will be in a concentrated condition ready to be calcined by the VDC in room 230C. The oxide product of the VDC will be placed into the 2736-Z vaults for long term storage.},
doi = {10.2172/16903},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 23 00:00:00 EDT 1997},
month = {Wed Apr 23 00:00:00 EDT 1997}
}

Technical Report: