Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Initial Implementation of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control

Journal Article · · Rapid Communications in Mass Spectrometry, 17(7):627-636
DOI:https://doi.org/10.1002/rcm.955· OSTI ID:15010173
Capillary LC separation coupled with external accumulation FTICR mass spectrometry has recently been demonstrated to have significant potential for proteomics research. Accumulation of an excessive space charge in an external to the FTICR cell ion trap has been shown to result in increased mass measurement error, undesirable ion discrimination and/or fragmentation, and potentially causing misrepresentation or incorrect assignments of lower abundance peptides in the acquired mass spectra. In this work we report on the capability of data-dependent adjustment of ion accumulation times in the course of LC separations, further referred to as Automated Gain Control (AGC). Three different AGC approaches were evaluated based upon the number of putative peptides from a tryptic digest of four casein proteins detected in the course of LC/FTICR separations. AGC was found to increase by up to a factor of 3 the number of peptides identified compared to the conventional technique.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
15010173
Report Number(s):
PNNL-SA-37927; KP1102010
Journal Information:
Rapid Communications in Mass Spectrometry, 17(7):627-636, Journal Name: Rapid Communications in Mass Spectrometry, 17(7):627-636
Country of Publication:
United States
Language:
English

Similar Records

Automated Gain Control and Internal Calibration With External Ion Accumulation Capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance.
Journal Article · Fri Aug 15 00:00:00 EDT 2003 · Analytical Chemistry · OSTI ID:15005588

Design and Performance of an ESI Interface for Selective External Ion Accumulation Coupled to a Fourier Transform Ion Cyclotron Mass Spectrometer
Journal Article · Thu Nov 30 23:00:00 EST 2000 · Analytical Chemistry · OSTI ID:15001373

An Automated High Performance Capillary Liquid Chromatography Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for High-Throughput Proteomics
Journal Article · Sat Jan 31 23:00:00 EST 2004 · Journal of the American Society for Mass Spectrometry, 15(2):212-232 · OSTI ID:15010460

Related Subjects