Automated Gain Control and Internal Calibration With External Ion Accumulation Capillary liquid chromatography-electrospray ionization-fourier transform ion cyclotron resonance.
- VISITORS
- BATTELLE (PACIFIC NW LAB)
When combined with capillary LC separations, Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (ESI-FTICR MS) has increasingly been applied for advanced characterization of proteolytic digests. Incorporation of external (to the ICR cell) ion accumulation multipoles with FTICR for ion pre selection and accumulation has enhanced the dynamic range, sensitivity and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in overfilling of the external trap, resulting in m/z discrimination and fragmentation of peptide ions. An excessive space charge trapped in the ICR cell causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) for protein identification. To eliminate m/z discrimination in the external ion trap, further increase the duty cycle and improve MMA, we developed a capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as Automated Gain Control (AGC), in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The system was initially evaluated in the analysis of a 0.5 mg/mL tryptic digest of bovine serum albumin. The implementation of LC/ESI/AGC/FTICR with internal calibration gave rise to a {approx} 10-fold increase in the number of identified tryptic peptides within mass measurement accuracy of 2 ppm as compared to that detected during the conventional LC/FTICR run with a fixed ion accumulation time and external calibration.
- Research Organization:
- Pacific Northwest National Lab., Richland, WA (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC06-76RL01830
- OSTI ID:
- 15005588
- Report Number(s):
- PNNL-SA-37925; KP1102010
- Journal Information:
- Analytical Chemistry, Journal Name: Analytical Chemistry Journal Issue: 16 Vol. 75
- Country of Publication:
- United States
- Language:
- English
Similar Records
Initial Implementation of external accumulation liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance with automated gain control
Design and Performance of an ESI Interface for Selective External Ion Accumulation Coupled to a Fourier Transform Ion Cyclotron Mass Spectrometer
Increased Protein Identification Capabilities Through Novel Tandem MS Calibration Strategies
Journal Article
·
Fri Jan 31 23:00:00 EST 2003
· Rapid Communications in Mass Spectrometry, 17(7):627-636
·
OSTI ID:15010173
Design and Performance of an ESI Interface for Selective External Ion Accumulation Coupled to a Fourier Transform Ion Cyclotron Mass Spectrometer
Journal Article
·
Thu Nov 30 23:00:00 EST 2000
· Analytical Chemistry
·
OSTI ID:15001373
Increased Protein Identification Capabilities Through Novel Tandem MS Calibration Strategies
Journal Article
·
Mon Aug 01 00:00:00 EDT 2005
· Journal of Proteome Research, 4(4):1434-1441
·
OSTI ID:913610