Improve Replication of In-service Mechanical Environments

Technical Report ·
DOI:https://doi.org/10.2172/1493833· OSTI ID:1493833
 [1];  [1];  [1]
  1. Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

Structural dynamic testing is a common method for determining if the design of a component of a system will mechanically fail when deployed into its field environment. To satisfy the test's goal, the mechanical stresses must be replicated. Structural dynamic testing is commonly executed on a shaker table or a shock apparatus such as a drop table or a resonant plate. These apparatus impart a force or load on the component through a test fixture that connects the unit under test to the apparatus. Because the test fixture is directly connected to the unit under test, the fixture modifies the structural dynamics of the system, thus varying the locations and relative levels of stress on the unit under test. This may lead to a false positive or negative indication if the unit under test will fail in its field environment depending on the environment and the test fixture. This body of research utilizes topology optimization using the Plato software to design a test fixture that attaches to the unit under test that matches the dynamic impedance of the next level of assembly. The optimization's objective function is the difference between the field configuration and the laboratory configuration's frequency response functions. It was found that this objective function had many local minima and posed difficulties in converging to an acceptable solution. A case study is presented that uses this objective function and although the results are not perfect, they are quantifiably better than the current method of using a sufficiently stiff fixture.

Research Organization:
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
DOE Contract Number:
AC04-94AL85000; NA0003525
OSTI ID:
1493833
Report Number(s):
SAND--2018-10187; 672090
Country of Publication:
United States
Language:
English

Similar Records

A simulation study of test fixture attachment points for vibration test optimization (MEEN 5440 Final Project)
Technical Report · Thu May 04 00:00:00 EDT 2023 · OSTI ID:1973785

FY18 ASC P&EM L2 Milestone 6356: Improve Replication of In-service Mechanical Environments. Executive Summary
Technical Report · Thu Sep 06 00:00:00 EDT 2018 · OSTI ID:1760402

Optimization of an Impedance-Matched Test Fixture with the Modal Projection Error
Journal Article · Mon Apr 07 00:00:00 EDT 2025 · Experimental Techniques · OSTI ID:2584286

Related Subjects